Port Direction Function
clk In Clock input
ce In Clock enable; unused
ref_clk In Reference clock for time stamping
reset In Master reset. Clears all pending events and FIFO.
d[31:0] In Data bus input.
event_in[31:0] In Event inputs. Rising edge of event inputs causes the
event log to make an alert record.
event_marker[31:0] In The event marker is put in the event message as word
3.
event_class Out Event class signifies what type of alert is generated. For
event inputs 15..0, this is 1; for event inputs 31..16 this
is 0.
timestamp_run In Enables the time stamp counter to run.
ad_error_channel[7:0] In
dac_error_channel[7:0] In
event_dout[31:0] Out The output data from the alert FIFO.
event_fifo_not_empty Out When true, the event_fifo is not empty. More alert
messages, or a partial alert message, are in the FIFO.
event_fifo_rd In When true, this reads the alert FIFO. This signal must
be synchronous to clk. Each clock period will advance
the FIFO one element.
event_fifo_rst In Resets the event FIFO.
user_event_wr In An alert message may be created by writing to the data
port and asserting user_event_wr.
event_log_busy Out When true, the event log is busy creating a message.
Table 22: ii_event_log Component Ports
Target Device : Any Xilinx device