CY8C21634/CY8C21534
CY8C21434/CY8C21334/CY8C21234
Document Number: 38-12025 Rev. *Q Page 19 of 45
Absolute Maximum Ratings
Operating Temperature
Symbol Description Min Typ Max Units Notes
T
STG
Storage Temperature -55 25 +100
o
C Higher storage temperatures
reduce data retention time. Recom-
mended storage temperature is
+25
o
C ± 25
o
C. Extended duration
storage temperatures above 65
o
C
degrade reliability.
T
A
Ambient Temperature with Power Applied -40 – +85
o
C
Vdd Supply Voltage on Vdd Relative to Vss -0.5 – +6.0 V
V
IO
DC Input Voltage Vss -
0.5
– Vdd +
0.5
V
V
IOZ
DC Voltage Applied to Tri-state Vss -
0.5
– Vdd +
0.5
V
I
MIO
Maximum Current into any Port Pin -25 – +50 mA
ESD Electro Static Discharge Voltage 2000 – – V Human Body Model ESD.
LU Latch-up Current – – 200 mA
Symbol Description Min Typ Max Units Notes
T
A
Ambient Temperature -40 – +85
o
C
T
J
Junction Temperature -40 – +100
o
C The temperature rise from ambient
to junction is package specific. See
Table 38 on page 39. The user must
limit the power consumption to
comply with this requirement.
[+] Feedback