Cypress Semiconductor CY8CNP102E Manual do Utilizador Página 2

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 9
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 1
CE54939
August 9, 2011 Document No. 001-54939 Rev *C 2
UART
Parameter Value Comments
Rx Clock Out None Not used
Tx Clock Out None Not used
InvertRX Input
Normal
Do not invert Rx Input
Note The clock to the TX8 user module should be eight times the desired baud rate. The parameters Command Terminator, ParamDelimiter,
and IgoneCharsBelow are used by the high level UART API to process the commands received. When the UART receives the character set
as Command Terminator, the API reports through a flag that a valid command has been received. When the character set as ParamDelimiter
is encountered, the API understands that the characters that follow the ParamDelimiter are the next parameter in the command. The API
ignores any characters below the value set in IgonreCharsBelow value and does not store them in the command buffer.
Global Resources
Important Global Resources
Parameter Value Comments
CPU_Clock SysClk/2 Sets the CPU frequency to 12 MHz
VC3 Source SysClk/1 Set System Clock as the source for VC3
VC3 Divider 156 Divide 24 MHz system clock by 156 (effective baud rate is 19.2 kbps)
Note Leave all other global resources at their default.
Pin Configuration
Pin Select Drive Interrupt
P2 [7] GlobalOutEven_7 Strong DisableInt
P2 [5] GlobalInEven_5 High Z DisableInt
Hardware Connections
Figure 1.Schematic Diagram
MAX232, a RS232 transceiver, is used to translate the ±10 V RS232 signals to transistor-transistor logic (TTL) level signals of
the PSoC.
JP1 is a 9 pin female serial port connector is used to connect the project with a PC.
Vista de página 1
1 2 3 4 5 6 7 8 9

Comentários a estes Manuais

Sem comentários